Withdrawal
Disconnect the negative cable from the battery.
Isolate the negative battery terminal to prevent accidental connection.
Remove the air filter. Remove the fan clutch.
Remove poly V-belt.
Remove the ventilation hose from the back of the generator.
On the back of the generator, pull the plug off the D+ terminal by pressing down on the wire harness.
Remove the B+ connection cover. Unscrew the nut and remove the thick wire.
Loosen the mounting bolts and remove the alternator.
Installation
Installation is carried out in the reverse order of removal.
Removing the Bosch generator
Remove poly V-belt (1) and generator (2).
Loosen the three screws (6) and remove the protective cover of the generator.
Loosen two screws (4) voltage regulator mounts (3) from the rear of the generator and carefully remove the regulator.
Replace guards (2), when their length is less than 5 mm. To do this, solder the connections.